We introduce our 20000LPH RO Water Treatment Plant designed to deliver continuous 20 m3/h output for demanding industry needs in Venezuela. Our team engineers the full system to ensure stable product quality and high uptime. You can expect robust pre-treatment, precise reverse osmosis trains, and clear process integration.
Using 0.001 μm membranes from brands like Filmtec, Toray, LG, and Vontron, we remove salts, organics, and microorganisms with high recovery and low waste.
We provide clear P&IDs, factory testing, and on-site commissioning. Our team supports installation and operator training, so the system is ready for production fast.
Contact us via Mobile/WhatsApp/WeChat +8616616636489 or email info@chunkewatertreatment.com to request a reverse osmosis plant diagram or a site-specific quote.
Our Systems
Overview: High-capacity reverse osmosis system engineered for dependable pure water production
We engineer high-capacity reverse osmosis systems that deliver stable, production-grade pure water for industrial sites in Venezuela. Our approach pairs robust pretreatment with a compact core to keep output steady and meet strict quality targets.
Typical process flow runs: raw water tank → raw water pump → quartz sand filter → activated carbon filter → security filter → high pressure pump → reverse osmosis system → UV sterilizer → pure water tank. The desalination rate reaches 97–99% and online conductivity meters monitor quality continuously.
- Dependable production: Balanced throughput and consistent specifications for demanding processes.
- Modular equipment: Serviceable design to reduce downtime and ease maintenance.
- Design support: We supply diagrams and engineering guidance for approvals and installation.
| Stage | Function | Typical Metric |
| Pretreatment | Remove solids, chlorine, and organics to protect membranes | Turbidity |
| Reverse Osmosis Core | High-efficiency desalination and contaminant rejection | Desalination 97–99%; configured to required lph |
| Monitoring & Output | Continuous conductivity and storage stabilization | Real-time conductivity; steady tank supply |
Contact us for a reverse osmosis plant diagram and site-specific layout. Call +8616616636489, email info@chunkewatertreatment.com, or visit www.chunkewatertreatment.com. Follow Facebook @ChunkeOfficial and Instagram @David_Chunke for updates.
20000LPH RO Water Treatment Plant
For a nominal 20 m³/h capacity we size arrays, pumps, and controls so throughput and recovery stay steady across raw feed changes. Our design targets 70–75% recovery and typical operating pressure between 1.0–1.4 MPa.
Flow rate, recovery, and pressure profile
We configure multiple 8-inch pressure vessels and membranes to meet the 20000 lph rating and expected flux. The RO segment usually needs about 30 kW installed power and a high pressure pump sized for net driving pressure.
Typical configuration and footprint considerations
Standard flow path: raw water → raw water pump → quartz sand → activated carbon → security cartridge (5 μm) → high pressure pump → osmosis → UV → pure tank.
- Protection: 5 μm water filter elements to reduce membrane fouling.
- Flexibility: extra pump head and throttling valves for raw water variability.
- Serviceability: compact skid with aisles for membrane pull-outs and maintenance.
We engineer and manufacture to specification. Request our P&ID and consult our engineers: +8616616636489, info@chunkewatertreatment.com.
How reverse osmosis works and our process flow from raw water to pure water
A clear process flow keeps feed steady and protects membranes while delivering high-quality permeate. We begin with a buffered raw water tank that evens out supply and avoids pump cycling. A booster water pump then feeds pretreatment at steady pressure so downstream media perform predictably.
Raw water tank and booster pump stabilization
We size the water tank to provide continuous feed and dampen pressure swings. The water pump stabilizes flow so filters see consistent head and longevity improves.
Quartz sand filtration for turbidity and suspended solids
A quartz sand filter removes turbidity, suspended matter, and colloids. This lowers SDI and protects the next stages from fouling.
Activated carbon filtration for color, odor, and residual chlorine removal
Our carbon filter strips color, odor, organics, and residual chlorine. This prevents oxidative damage to sensitive membrane surfaces.
Security/cartridge filter and optional water softener for membrane protection
A 5 μm cartridge security filter captures fines and most microbes before the separation stage. Where feed hardness is high, a sodium ion-exchange softener reduces Ca2+/Mg2+ to cut scaling risk.
High pressure pump, membranes, UV sterilizer, and pure water tank
The high pressure pump establishes the net driving pressure across 0.001 μm membranes from trusted brands to reject salts, organics, and microorganisms. A UV sterilizer polishes permeate before the permeate tank to minimize regrowth.
- We design and manufacture pretreatment, softeners, and post-treatment to match local raw feed conditions in Venezuela.
- We document the full sequence in a clear process diagram so your operators can operate and maintain the system safely.
- Request our layout and pricing details via reverse osmosis plant pricing or contact us at +8616616636489 / info@chunkewatertreatment.com.
Core system components we design, engineer, and manufacture
We manufacture core components from pretreatment housings to hygienic storage so each plant arrives ready for fast commissioning. Our scope covers media vessels, skids, and distribution equipment engineered for industrial duty in Venezuela.
Pretreatment systems
We build filter housings in FRP or stainless steel and fill them with quartz sand or activated carbon per feed analysis. Automatic softeners use cation resin for smart regeneration to lower hardness and extend membrane life.
RO skid and instrumentation
The skid integrates pressure vessels, manifolds, valves, and gauges with PLC/Relay and HMI control options. We instrument for pressure differential, flow, and conductivity to enable proactive maintenance.
Post-treatment and storage
Post-treatment includes UV sterilizers and a hygienic pure tank with distribution pumps to points of use. All products are factory-tested and come with P&IDs, electrical diagrams, and manuals.
“We deliver complete equipment suites with factory testing to reduce onsite commissioning time.”
Contact us: +8616616636489 | info@chunkewatertreatment.com | www.chunkewatertreatment.com
Membranes, pumps, and materials selected for efficiency and longevity
We focus on matching element selection and pump curves so the system runs efficiently year-round. Component choice reduces downtime and keeps operating costs low in coastal and industrial sites across Venezuela.
Membrane elements with 0.001 μm precision remove up to 97–99% of salts and bacteria while preserving sustainable flux. We specify brands such as Filmtec, Toray, LG, and Vontron to suit feed chemistry and required rejection.
Energy-efficient pumps and corrosion-resistant materials
We size energy-efficient high pressure pumps (CNP or customer-specified) to maintain steady production under changing temperature and salinity. Hydraulic profiles are optimized to reduce pressure drop and membrane stress.
- Clean-in-place and automatic flushing extend run times and limit fouling.
- Differential pressure and quality sensors alert operators before performance declines.
- Coatings and stainless alloys resist corrosion for long service life in coastal environments.
We engineer and manufacture these modules to lower lifecycle cost. Request a detailed plant diagram and specification support from our team.
“Each system is built for consistent performance with minimal maintenance.”
Performance, water quality targets, and low operation cost
Performance metrics drive every design choice, ensuring steady production and manageable operating budgets. We set clear targets for desalination and water quality so the system meets process and regulatory needs.
Desalination rate, conductivity control, and recovery optimization
Our systems achieve up to 97–99% desalination with online conductivity meters for continuous quality monitoring. Recovery is engineered around 70–75% for 20000 lph to balance yield and membrane health.
Lorem ipsum dolor sit amet, consectetur adipiscing elit. Ut elit tellus, luctus nec ullamcorper mattis, pulvinar dapibus leo.
Design choices that reduce energy and maintenance costs
We use automated flushing, optimized hydraulics, and targeted pretreatment to cut energy use and cleaning frequency. Material selection and efficient pumps lower operation cost without sacrificing reliability.
- Cleaning triggers set by differential pressure and quality trends protect membranes.
- UV and pretreatment reduce microbiological fouling by bacteria and stabilize quality.
- Acceptance testing and documented protocols confirm performance at commissioning.
We provide engineered systems with lifetime support. Request diagrams and consultation via project updates or contact +8616616636489 / info@chunkewatertreatment.com.
Automation, protections, and control options for reliable operation
We design control layers that make daily operation predictable and safe 20000LPH RO Water Treatment Plant. Our PLC/HMI packages provide clear status, alarms, and trending so operators see key metrics at a glance.
PLC/HMI control with continuous conductivity monitoring
Our PLC/HMI gives real‑time conductivity, pressure, and flow readouts. Remote access and alarm histories help engineers tune the system and reduce unplanned downtime.
Auto start/stop, shortage, and pressure protections
The controller auto-starts when the pure tank needs make-up and stops at high level to avoid overflow.
Water shortage interlocks protect multi-stage pumps. Low and high pressure trips safeguard membranes and the high pressure pump from upset.
Automatic membrane flushing and energy controls
Timed auto flush and backwash reduce fouling and extend run times. We add VFDs on pumps to stabilize pressure, lower spikes, and contribute to low operation cost.
| Feature | Function | Trigger / Condition |
| PLC/HMI | Control, trending, remote access | Operator login / network |
| Tank auto-start/stop | Prevent overflow & maintain supply | High/low level sensors |
| Pressure interlocks | Protect membranes and pump | Low/high pressure switches |
| Auto flush/backwash | Reduce fouling and cleaning frequency | Timed cycle or differential pressure |
We provide detailed manuals, safe start/stop sequences, and remote support on request. For diagrams and the detailed specifications and business insights, contact us at +8616616636489 or info@chunkewatertreatment.com. 20000LPH RO Water Treatment Plant.
Applications and industry use cases across Venezuela
We tailor our systems to meet specific industry needs across Venezuela, from coastal utilities to inland factories. Our scope covers continuous, automated units that lower operating cost and extend service life.
We supply reverse osmosis, UF, EDI, pretreatment, and softeners as integrated products and equipment for process-critical sites. These solutions serve electronics, power systems, metallurgical, chemical, medical and pharmaceutical, and food & beverage sectors.
Key industry benefits
- Food & beverage: stable process feed preserves taste and formula consistency.
- Pharmaceuticals & medical: pretreated output meets strict quality rules for production and labs.
- Power & electronics: low conductivity and reduced scaling protect sensitive systems.
- Metallurgy & chemical: rugged equipment performs in harsh conditions.
- Brackish and wastewater: systems handle coastal brackish intakes and polishing for reuse.
- We provide industrial-grade water filter solutions and products sized for duty; not intended as a home water purifier.
“Each installation is customized to site intake, space, and standards to ensure uptime and compliance.”
Ask us for a tailored diagram and specification for your project. Contact +8616616636489 or info@chunkewatertreatment.com to discuss a plant layout and local service coordination.
Installation, commissioning, and lifetime support
We handle on-site setup, electrical integration, and startup verification so your system meets performance and safety targets. Our approach reduces handover time and minimizes surprises during first runs.
On-site setup, training, and operation manuals provided
Our technicians supervise installation, confirm flows and pressures, and integrate Relay/PLC/HMI controls with your SCADA or DCS. We provide hands-on operator training that covers normal operation, troubleshooting, and membrane protection.
We supply full documentation including GAs, P&IDs, utility lists, and tailored maintenance schedules. High-definition photos and videos are available for your marketing and stakeholder reporting.
Factory quality assurance, 12-month warranty, and ongoing maintenance
- 100% factory QA tests validate function and integrity before shipment to Venezuela.
- A 12-month warranty and lifetime maintenance support protect your investment.
- We stock critical spares and recommend local alternates to cut downtime.
- As a specialist company and technology co., we provide sustained technical assistance as needs evolve.
“Factory-tested, field-supported commissioning shortens time to stable operation.”
Compare similar products and scale your plant capacity
We design and manufacture a full range of capacities so operators in Venezuela can standardize equipment across multiple sites. Our lineup spans small test units to large arrays, making it simple to match supply with demand.
Model capacities range from 0.25 m3/h to 50 m3/h+. Typical recoveries fall between 50–75% and operating pressure is usually 1.0–1.4 MPa. A 20 m3/h (20000LPH RO Water Treatment Plant) model targets 70–75% recovery and uses about 30 kW for the separation stage.
Capacity guidance and decision points
- Standardize: use similar products from 0.25 to 50+ m3/h to simplify spares and training.
- Scale predictably: arrays, vessel counts, and pumps scale with your lph target.
- Optimize: we compare recovery, pressure, and energy to find the best fit for site conditions.
| Capacity Range | Recovery (%) | Typical Pressure (MPa) | Estimated RO Power (kW) |
| 0.25 – 1 m3/h (small) | 50 – 65 | 1.0 – 1.2 | 1 – 3 |
| 1 – 20 m3/h (mid) | 60 – 72 | 1.0 – 1.3 | 3 – 30 |
| 20 – 50+ m3/h (large) | 65 – 75 | 1.1 – 1.4 | 30 – 100+ |
Contact us to size your reverse osmosis system and review CAPEX/OPEX comparisons. Call +8616616636489 or email info@chunkewatertreatment.com to request diagrams and a tailored quote.
Request a reverse osmosis plant diagram and talk to our engineers
Request a site-specific diagram so our engineers can map piping, pumps, and controls to your location. We explain sizing, instrumentation, and layout in clear, Spanish-capable guidance for projects across Venezuela.
Contact us to review options for PLC/HMI or PC program controllers, automatic start/stop by tank level, membrane auto flush/backwash, and low/high pressure protection. Online conductivity monitoring and shortage interlocks are part of our standard control suite.
Key support we provide:
- Tailored diagram showing piping, flow, and instrumentation for your site.
- Engineer sizing for the water pump and vessel arrays plus pump and tank strategy for buffering and storage.
- Control options with remote support to simplify operator workflows and reporting.
- Specification of pretreatment media, cartridge water filter choices, and cleaning strategies.
- Integration planning with utilities, safety systems, and data reporting.
Contact us: Mobile/WhatsApp/WeChat +8616616636489 | www.chunkewatertreatment.com | info@chunkewatertreatment.com for 20000LPH RO Water Treatment Plant.
Reach out on Facebook @ChunkeOfficial or Instagram @David_Chunke for fast feedback and document exchange.
“We share clear proposals with scope, performance guarantees, and delivery timelines to help you move from purifier concept to industrial design.”
Conclusion
We combine proven reverse osmosis design with active monitoring to deliver reliable purification and consistent quality. Our 0.001 μm membranes remove up to 97–99% of salts and bacteria while automated protections (low/high pressure, auto flush/backwash) preserve membrane life.
The osmosis system pairs layered filtration, including a carbon filter and security cartridges, with instrumented pumps and conductivity meters to simplify daily operation. We back each product with factory QA, a 18-month warranty, and lifetime support.
For site studies, membrane selection, or to review the best water treatment plant from China, contact us at +8616616636489 or info@chunkewatertreatment.com. Follow Facebook @ChunkeOfficial and Instagram @David_Chunke.